📖
STAR-XPC: Set Transformer for Estimating X-ray Transmission in Polymer Composites
Can Erer, H. Birkan Yilmaz, Nebahat Aral

STAR-XPC: Set Transformer for Estimating X-ray Transmission in Polymer Composites

Science & Mathematics Published 2026 Verification Pending

Overview & Synopsis

Evaluating the energy transmission ratio of an X-ray beam through a polymer composite is a challenging task in radiation shielding studies. The reference solution with Monte Carlo transport simulation is highly accurate but computationally expensive: each of our reference simulations is capped at $4\times10^9$ photon histories and a 20,000 s (over 5 hours) time limit, while closed-form analytical methods fail to represent such complex scenarios. We present an artificial neural network model that maps the unordered multi-set of molecular constituents, their mass fractions, and four bulk physical descriptors directly to the transmission ratio $I(t)/I_0$ in 1-3 milliseconds. The model is a Set Transformer, which makes it permutation invariant by construction and accepts mixtures of different sizes up to 11 constituents within a fixed-size padded set. Each constituent is embedded with a chemistry-pretrained transformer language model, ChemBERTa. In our proposed method, training data are produced by an automated PENELOPE/penEasy pipeline using the radiation source at 30, 80, 100, and 120 kV tube voltages over polyethylene-based shielding composite slabs of thicknesses spanning 0.15-2.5 mm. After preprocessing, the dataset contains $n = 4697$ simulated configurations on which a leakage-free, jointly stratified 10-fold cross-validation is performed, attaining mean squared error MSE = $(1.12 \pm 0.56)\times10^{-4}$, normalized-MSE percentage NMSE% = 0.0294% $\pm$ 0.0147%, and $R^2 = 0.9988$. The corresponding per-sample percentage errors give an alpha-trimmed ($α= 0.10$) absolute percentage error (APE) of 1.66% and a median APE of 1.15%. Our model's inference is several orders of magnitude faster than the underlying Monte Carlo simulation (sub-millisecond per query vs. several hours for the reference run) with effective accuracy in predicting $I(t)/I_0$.

Indexed from repository: arXiv (arxiv.org)
Loading document from verified source...
Keyboard Shortcuts: ← / → for pages • + / - for zoom • 0 to fit width Powered by Mozilla PDF.js v3.11

Document Information

Document Title STAR-XPC: Set Transformer for Estimating X-ray Transmission in Polymer Composites
Author / Organization Can Erer, H. Birkan Yilmaz, Nebahat Aral
Subject & Discipline cs.LG
Categories Science & Mathematics
Publication Year 2026
License / Rights arXiv Open Access / Creative Commons
Resource Verification Listed PDF (Verification Pending)
Original Host Website arXiv (arxiv.org)
File Format application/pdf (Portable Document Format)
Language EN
Catalog ID DOC-269795
Original Source Link Visit Source Page on arxiv.org »