๐Ÿ“–
Context-Augmented, Session-Calibrated Blood Pressure Tracking from Photoplethysmography
Farouk Ganiyu Adewumi, Timothy Oladunni

Context-Augmented, Session-Calibrated Blood Pressure Tracking from Photoplethysmography

Science & Mathematics Published 2026 Verification Pending

Overview & Synopsis

Objective.To distinguish the contributions of acquisition context and photoplethysmography (PPG) to session-calibrated blood pressure (BP) tracking.Approach. The original comparison used three repeats of five-fold participant-level cross-validation in 653 AuroraBP participants, excluding calibration-labelled prediction targets. Matched analyses separated context and PPG and removed elapsed-time terms. Later exploratory follow-ups retained PPG, accelerometer signals and three initial cuff readings. Separate studies evaluated pulse-rate fusion and an intraoperative VitalDB model. Main results.The original wearable-state model achieved participant-level mean absolute errors (MAEs) of 7.697/6.139 mmHg for systolic/diastolic BP (SBP/DBP). Added context reduced MAE by 0.436/0.126 mmHg (97.5% intervals 0.305-0.573/0.053-0.200). In the matched factorial without the external PPG prior, PPG improved on calibration, time and protocol-provided posture/activity by 0.214/0.135 mmHg; removing time left the DBP interval including zero. Standard PPG descriptors contributed, but additional nonlinear/attractor benefit was not established. In a separate follow-up series, a sensor-history ensemble achieved 7.299/5.445 mmHg versus its static-rich reference's 7.363/5.470, small gains of 0.064/0.025 mmHg. Larger DBP errors did not improve uniformly. Quality-weighted fusion reduced pulse-rate MAE from 3.985 to 3.690 beats per minute. VitalDB MAEs remained 15.375/8.833 mmHg despite small PPG gains. Significance. The contribution is a calibrated evaluation framework with explicit controls, reproducible feature-cache-to-results analyses and retained negative findings. The sensor-history gain is exploratory after repeated dataset reuse. Independently estimated wearable states, complete raw-signal reproduction of the supplied richer features, external transfer and clinical adequacy remain unestablished.

Indexed from repository: arXiv (arxiv.org)
Loading document from verified source...
Keyboard Shortcuts: ← / → for pages • + / - for zoom • 0 to fit width Powered by Mozilla PDF.js v3.11

Document Information

Document Title Context-Augmented, Session-Calibrated Blood Pressure Tracking from Photoplethysmography
Author / Organization Farouk Ganiyu Adewumi, Timothy Oladunni
Subject & Discipline cs.AI
Categories Science & Mathematics
Publication Year 2026
License / Rights arXiv Open Access / Creative Commons
Resource Verification Listed PDF (Verification Pending)
Original Host Website arXiv (arxiv.org)
File Format application/pdf (Portable Document Format)
Language EN
Catalog ID DOC-268917
Original Source Link Visit Source Page on arxiv.org »