📖
High-Precision Tungsten Isotopic Analysis by Multicollection Negative Thermal Ionization Mass Spectrometry Based on Simultaneous Measurement of W and O-18/O-16 Isotope Ratios for Accurate Fractionation Correction
Anne Trinquier, Mathieu Touboul, Richard J. Walker

High-Precision Tungsten Isotopic Analysis by Multicollection Negative Thermal Ionization Mass Spectrometry Based on Simultaneous Measurement of W and O-18/O-16 Isotope Ratios for Accurate Fractionation Correction

Science & Mathematics Published 2016 Verification Pending

Overview & Synopsis

Determination of the W-182/W-184 ratio to a precision of +/- 5 ppm (2 sigma) is desirable for constraining the timing of core formation and other early planetary differentiation processes. However, WO3- analysis by negative thermal ionization mass spectrometry normally results in a residual correlation between the instrumental-mass-fractionation-corrected (182)w/(184)w and W-183/W-184 ratios that is attributed to mass-dependent variability of 0 isotopes over the course of an analysis and between different analyses. A second-order correction using the W-183/W-184 ratio relies on the assumption that this ratio is constant in nature. This may prove invalid, as has already been realized for other isotope systems. The present study utilizes simultaneous monitoring of the O-18/O-16 and W isotope ratios to correct oxide interferences on a per-integration basis and thus avoid the need for a double normalization of W isotopes. After normalization of W isotope ratios to a pair of W isotopes, following the exponential law, no residual W-O isotope correlation is observed. However, there is a nonideal mass bias residual correlation between W-182/W-i and W-183/W-i with time. Without double normalization of W isotopes and on the basis of three or four duplicate analyses, the external reproducibility per session of W-182/W-184 and W-183/W-184 normalized to W-186/W-183 is 5-6 ppm (2 sigma, 1-3 mu g loads). The combined uncertainty per session is less than 4 ppm for 183W/184W and less than 6 ppm for 182W/184W (2 sigma(m)) for loads between 3000 and 50 ng.

Advertisement
SPONSOR CONTENT
Indexed from repository: HAL Open Science (hal.science)
Loading document from verified source...
Keyboard Shortcuts: ← / → for pages • + / - for zoom • 0 to fit width Powered by Mozilla PDF.js v3.11

Document Information

Document Title High-Precision Tungsten Isotopic Analysis by Multicollection Negative Thermal Ionization Mass Spectrometry Based on Simultaneous Measurement of W and O-18/O-16 Isotope Ratios for Accurate Fractionation Correction
Author / Organization Anne Trinquier, Mathieu Touboul, Richard J. Walker
Subject & Discipline Multidisciplinary Academic Open Research
Categories Science & Mathematics
Publication Year 2016
License / Rights Open Access / Creative Commons
Resource Verification Listed PDF (Verification Pending)
Original Host Website HAL Open Science (hal.science)
File Format application/pdf (Portable Document Format)
Language EN
Catalog ID DOC-16493
Original Source Link Visit Source Page on hal.science »