Automated prostate lesion detection from diffusion-weighted MR imaging (DWI) conventionally relies on reconstructed images and does not fully use all acquisition information. We present an end-to-end network that uses complex multicoil DWI data and coil sensitivity information for prostate lesion segmentation. We included 269 fastMRI prostate examinations with additional voxel-level lesion annotations. Of these, 64 examinations contained PIRADS 4 or 5 lesions. The proposed network, VarNet-Seg, consists of a k-space variational network (VarNet) with six variational cascades and an image-space 3D segmentation U-Net. Comparator models used the same segmentation architecture with fully coil-combined images (CC-Seg), fixed root-sum-of-squares reconstruction (RSS-Seg), or fixed SENSE reconstruction (SENSE-Seg). We performed ablations with end-to-end training and data consistency (DC) enabled or disabled. We evaluated lesion segmentation using Dice and patient-level detection using AUROC in five-fold cross-validation with full sampling, simulated undersampling, added noise, or both. VarNet-Seg achieved the highest Dice at every undersampling level. At eight-fold acceleration, Dice was 0.22 for VarNet-Seg, 0.14 for SENSE-Seg and 0.16 for VarNet-Seg (no DC). The paired difference from SENSE-Seg was 0.08 (95% CI, 0.04-0.11). With full sampling, VarNet-Seg and RSS-Seg performed similarly (0.40 vs 0.39). Patient-level AUROC decreased from 0.75 with full sampling to 0.63 at eight-fold acceleration; corresponding RSS-Seg AUROCs were 0.76 and 0.64. The proposed multicoil network improved prostate lesion segmentation under simulated undersampling compared to conventional models. Matched ablations supported contributions from both end-to-end training and data consistency. Prospective evaluation is needed to establish whether this approach can be used clinically in accelerated prostate DWI.

Indexed from repository: arXiv (arxiv.org)
Loading document from verified source...
Keyboard Shortcuts: ← / → for pages • + / - for zoom • 0 to fit width Powered by Mozilla PDF.js v3.11

Document Information

Document Title End-to-end prostate lesion segmentation and detection from undersampled diffusion-weighted MRI
Author / Organization Lukas T. Rotkopf, Marco Schlimbach, Kevin Kröninger, Stefan O. Schoenberg, Heinz-Peter Schlemmer, Jens Kleesiek, Moritz Rempe
Subject & Discipline cs.CV
Categories Computer Science & Mathematics
Publication Year 2026
License / Rights arXiv Open Access / Creative Commons
Resource Verification Listed PDF (Verification Pending)
Original Host Website arXiv (arxiv.org)
File Format application/pdf (Portable Document Format)
Language EN
Catalog ID DOC-114575
Original Source Link Visit Source Page on arxiv.org »