Home »
Academic Articles »
C »
Approaching the Quantum Limit in Axion Detection at IBS-CAPP and IBS-DMAG
Approaching the Quantum Limit in Axion Detection at IBS-CAPP and IBS-DMAG
Sergey V. Uchaikin
(Dark Matter Axion Group (DMAG), Institute for Basic Science (IBS), 193 Munji-ro, Daejeon 34051, Republic of Korea)
Boris I. Ivanov
(Dark Matter Axion Group (DMAG), Institute for Basic Science (IBS), 193 Munji-ro, Daejeon 34051, Republic of Korea)
Arjan F. van Loo
(RIKEN Center for Quantum Computing (RQC), Wako 351-0189, Saitama, Japan)
Yasunobu Nakamura
(RIKEN Center for Quantum Computing (RQC), Wako 351-0189, Saitama, Japan)
MinSu Ko
(Center for Axion and Precision Physics Research (CAPP), Institute for Basic Science (IBS), 193 Munji-ro, Daejeon 34051, Republic of Korea)
Jinmyeong Kim
(Center for Axion and Precision Physics Research (CAPP), Institute for Basic Science (IBS), 193 Munji-ro, Daejeon 34051, Republic of Korea)
Saebyeok Ahn
(Dark Matter Axion Group (DMAG), Institute for Basic Science (IBS), 193 Munji-ro, Daejeon 34051, Republic of Korea)
Seonjeong Oh
(Dark Matter Axion Group (DMAG), Institute for Basic Science (IBS), 193 Munji-ro, Daejeon 34051, Republic of Korea)
Yannis K. Semertzidis
(Center for Axion and Precision Physics Research (CAPP), Institute for Basic Science (IBS), 193 Munji-ro, Daejeon 34051, Republic of Korea)
SungWoo Youn
(Dark Matter Axion Group (DMAG), Institute for Basic Science (IBS), 193 Munji-ro, Daejeon 34051, Republic of Korea)
Journal: Physical Sciences Forum
•
• MDPI AG
• ISSN: 2673-9984
Abstract
We present the development of two complementary amplifier architectures for axion haloscope experiments, based on two types of Josephson Parametric Amplifiers (JPAs). The first employs a multi-chip module of flux-driven JPAs in a parallel–series configuration, enabling near quantum-limited amplification over an extended tunable range of between 1.2 and 1.5 GHz. The second design features a lumped-element JPA, offering continuous tunability across a wide frequency range from 2.4 to 4 GHz. Both approaches demonstrate near-quantum-limited noise performance and are compatible with operation in cryogenic environments. These amplifiers significantly enhance the sensitivity and frequency coverage of axion search experiments, and also provide new opportunities for broadband quantum sensing applications.
Sergey V. Uchaikin, Boris I. Ivanov, Arjan F. van Loo, et al. (2025). "Approaching the Quantum Limit in Axion Detection at IBS-CAPP and IBS-DMAG". Physical Sciences Forum. https://doi.org/10.3390/psf2025011005